Conair Hopper Temperature Controller UGD031 Manuel d'utilisateur Page 36

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 97
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 35
3-16 l Installation
Testing the Installation (continued)
7 Adjust the setpoint to the desired hopper inlet temperature. Use the
Setpoint Adjust or buttons to set the temperature. Move the heater enable
switch to the enable position. The temperature should stabilize around the set-
point and not significantly overshoot the set temperature.
8 If everything is working properly, the heater’s LED flashes and the tem-
perature climbs towards the setpoint.
For Carousel Plus Dryers
5
Reference the dryer manual and verify the dryer’s blower is running in the
correct direction and the dryer is ready for operation.
6 Start the dryer.
7 Adjust the setpoint to the desired hopper inlet temperature. Use the
Setpoint Adjust or buttons to set the temperature. Move the heater enable
s
witc
h to the enable position. The temperature should stabilize around the set-
point and not significantly overshoot the set temperature.
8 If e
v
erything is working properly, the heater’s LED flashes and the tem-
perature climbs towards the setpoint.
Heaters
Startup /
Shutdown
For Startup:
1. With heaters in
Standby, turn on
blower or dryer.
2. Enable heaters.
For Shutdown:
1. Switch heaters to
Standby. 
2. Wait 60 seconds
before turning off
blower or dryer.
Enable
Standby
Setpoint Adjust
Buttons
Vue de la page 35
1 2 ... 31 32 33 34 35 36 37 38 39 40 41 ... 96 97

Commentaires sur ces manuels

Pas de commentaire